MAKE-UP AIR

Direct-fired make-up air heaters work well in most types of construction applications, helping to control moisture and air contaminants. These heaters operate like a permanent air handler, providing evenly distributed, warm, dry air. Installed either inside or outside, E5MA Series heaters draw 100% fresh air through the units intake and discharge tempered air controlled by a remote thermostat.

Features:
• Electronic modulating burner controls and remote space thermostats automatically adjust gas flow, saving money on fuel costs

PRODUCTS

MODEL BTU/HR (MIN) BTU/HR (MAX) CFM NATURAL GAS PROPANE POWER SUPPLY (V/PH/A) DIMENSIONS L x W x H (IN) WEIGHT (LBS) BASE

E5MA-175

175,000
1,200
1⁄2″ NPT
1⁄2″ NPT
115/1/10
34″ x 24″ x 33″
215
CASTERS

E5MA-355

330,000
2,400
3⁄4″ NPT
3⁄4″ NPT
115/1/15
46″ x 32.5″ x 42″
390
CASTERS

E5MA-550

40,500
550,000
4,000
1″ NPT
1⁄2″ NPT
115/1/20
63″ x 33″ x 56″
600
CASTERS

E5MA-1500-1

61,000
1,500,000
8,000
1 1⁄4″ NPT
1″ NPT
208-230/1/30
74″ x 36″ x 68″
1,300
CASTERS

E5MA-1500-3

61,000
1,500,000
8,000
1 1⁄4″ NPT
1″ NPT
208-230/3/20
69″ x 37″ x 61″
1,300
CASTERS

E5MA-2300-3

111,275
2,300,000
12,000
1 1⁄2″ NPT
1″ NPT
208-230/3/30
98″ x 48″ x 54″
1,900
SKID

E5MA-2500-1

125,000
2,500,000
14,000
1 1⁄2’’ NPT
1″ NPT
208-230/1/50
100″ x 48″ x 60″
2,000
SKID

E5MA-2500-3

125,000
2,500,000
14,000
1 1⁄2’’ NPT
1″ NPT
208-230/3/30
100″ x 48″ x 60″
2,000
SKID

E5MA-4500

350,000
4,500,000
25,000
2″ NPT
1″ NPT
230/3/50 460/3/30
120″ x 62″ x 66″
3,000
SKID

MORE INFO

What Is Make-Up Air?
Make-up air is air from the outdoors that is heated and then evenly distributed indoors in a controlled manner to replace air that is being exhausted. This drier, tempered, fresh air has the ability to absorb the moisture and ventilate the fumes from the construction process. It provides lower relative humidity levels and dew point temperatures inside the building to prevent condensation and minimize the potential for mold.

Why Use Make-Up Air?
All buildings infiltrate, or “breathe.” This naturally occurring air movement happens when there is a temperature difference between the inside and the outside. Because buildings breathe, and because there are air contaminants (paint, adhesives, exhaust gases, etc.) and moisture during construction that need to be diluted/exhausted, it is desirable to mechanically control the process through the heater. E5 Energy’s make-up air heaters allow the introduction of controlled amounts of fresh, tempered air from the outside. A recirculating heater only attempts to control the temperature issue. It adds moisture from the combustion process, and relies on uncontrolled infiltration to ventilate.

Make-Up Air Heaters Provide:
• Controlled mechanical ventilation
• Lower dew point temperatures
• Reduced hot and cold spots
• More uniform interior and surface temperatures

Ordinary Recirculating Heaters:
• Intensify uncontrolled infiltration
• Recycle stale, dirty air
• Increase hot and cold spots
• Increase moisture and contaminant levels

GALLERY